¸ðµ¨: AGP3750-T1-AF
ÄÚÆà ±âÁ¾:AGP3750-T1-AF-M M Class (¸ÖƼ¹Ìµð¾î) / TFT Color LCD (65,536 »ö) / XGA
¼º´É»ç¾ç
Ç¥½Ã µð¹ÙÀ̽º |
TFT Color LCD |
µð½ºÇ÷¹ÀÌ »çÀÌÁî |
15" |
µð½ºÇ÷¹ÀÌ ÇØ»óµµ |
1,024 x 768 pixels (XGA) |
µµÆ®ÇÇÄ¡ |
W0.297 x H0.297 mm [W0.01 x H0.01 in.] |
À¯È¿ Ç¥½Ã Ä¡¼ö |
W306.2 x H230.1 mm [W12.06 x H9.06 in.] |
Ç¥½Ã»ö |
65,536 Colors (No blink)/16,384 Colors (Blink) |
¹é¶óÀÌÆ® |
When GP Revision 5 and later: LED (When replacement is required,contact your local GP distributor) When GP Revision 5 and earlier: CCFL (Replaceable)*1 |
ÈÖµµÁ¶Á¤ |
8 Levels (Adjusted with the touch panel) |
ÄÜÆ®¶ó½ºÆ® Á¶Á¤ |
Not applicable |
¹é¶óÀÌÆ® Æò±Õ¼ö¸í |
50,000 hrs. or more (continuous operation at 25¡É before backlight brightness decreases to 50% or backlight starts to blink) |
Ç¥½Ã ¹®ÀÚ Á¾·ù |
Japanese: 6,962 (JIS Standards 1 & 2) (including 607 non-kanji characters), ANK: 158 (Korean fonts, Simplified Chinese and Traditional Chinese fonts are downloadable. |
¹®ÀÚÅ©±â |
Standard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts, Stroke font: 6 to 127 pixel fonts, Image font: 8 to 72 pixel fonts |
¹®ÀÚ È®´ëÀ² |
Standard font: Width can be expanded up to 8 times. Height can be expanded up to 8 times.*2 |
Ç¥½Ã¹®ÀÚ¼ö |
1/4°¢ ¿µ¼ýÀÚ(8x8µµÆ®) |
128 char. x 96 rows |
1/2°¢ ¿µ¼ýÀÚ(8x16µµÆ®) |
128 char. x 48 rows |
ÇÑÀÚ(16x16µµÆ®) |
64 char. x 48 rows |
ÇÑÀÚ(32x32µµÆ®) |
32 char. X 24 rows |
ÄÁÆ®·Ñ¸Þ¸ð¸® |
º¯¼ö ¿µ¿ª |
SRAM 64 KB (uses lithium battery)*3 |
ÇÁ·Î±×·¥ ¿µ¿ª |
FLASH EPROM 132 KB |
¸Þ¸ð¸® ½ºÅÜ |
Equivalent to 15,000 steps*4 |
³»ºÎ ±â¾ï |
FLASH EPROM 16 MB (10 MB when the Event Recorder Function is in use)*5 |
¹é¾÷ ¸Þ¸ð¸® |
SRAM 320KB (uses lithium battery)*3 |
½Ã°£ Á¤È®µµ |
¡¾65 sec./month (deviation at room temperature and power is OFF)*6 |
ÅÍÄ¡ÆгΠ¹æ½Ä |
Resistive Film (analog) |
ÅÍÄ¡ÆгΠºÐÇØ´É |
1,024 X 1,024 |
ÅÍÄ¡ÆгΠ¼ö¸í |
1,000,000 times or more |
ÀÎÅÍÆäÀ̽º |
½Ã¸®¾ó(COM1) |
RS-232C/422/485, Asynchronous Transmission, Data Length: 7 or 8 bit, Parity: none, Even or Odd, Stop Bit: 1 or 2 bit, Data Transmission Speed: 2,400 bps to 115.2 kbps, Connector: D-Sub9 (plug) |
½Ã¸®¾ó(COM2) |
RS-422/485, Asynchronous Transmission, Data Length: 7 or 8 bit, Parity: none, Even or Odd, Stop Bit: 1 or 2 bit, Data Transmission Speed: 2,400 bps to 115.2 kbps, 187.5kbps (MPI), Connector: D-Sub9 (socket) |
ÀÌ´õ³Ý (LAN) |
IEEE802.3u,10BASE-T/100BASE-TX, Connector: Modular jack (RJ-45)¡¿1 |
È®Àå ¸ðµâ 1 |
Communication Expansion Unit x 1 |
È®Àå ¸ðµâ 2 |
VM/DVI Input Expansion Unit x 1 |
USB (TYPE-A) |
Conforms to USB1.1.(TYPE-A conn.) X 2, Power Supply Voltage: DC5V¡¾5%, Output Current: 500mA (max.), Communication Distance: 5m (max.) |
±â´ÉÈ®Àå ¸Þ¸ð¸® |
Function Expansion Memory x 1 (Inside interface cover) |
CF Ä«µå |
Compact Flash Card Slot (TYPE-II) x 1 |
ºñµð¿À ÀÔ·Â |
NTSC: 59.9Hz, PAL: 50Hz, SECAM: 50Hz, Connector: RCA 75¥Ø X 1 |
»ç¿îµå ÀÔ·Â |
MIC or LINE input (software switch), Connector: MINI-JACK ¥Õ3.5 x 1 |
»ç¿îµå Ãâ·Â |
Speaker Output, 70 mW (Rated Load: 8 ¥Ø, Frequency: 1 kHz), Connector: 2-piece terminal block (AUX) x 1 |
º¸Á¶ ÀÔÃâ·Â(AUX) |
Alarm Output, RUN Output, Buzzer Output, Rated Voltage: DC24V, Rated Current: 50mA, Remote Reset Input, Input Voltage: DC24V, Connector: 2-piece terminal block (AUX) X 1 |
- About the differences in a CCFL model and a LED model.
- Other font sizes can be set up with the Editor software.
- A Lithium battery's lifetime is:
10 years when the battery's ambient temperature is 40 oC or less. 4.1 years when the battery's ambient temperature is 50 oC or less. 1.5 years when the battery's ambient temperature is 60 oC or less. When used for back up: Approximately 100 days, with a fully charged battery. Approximately 6 days, with a half-charged battery.
- Up to 60,000 steps can be converted in software. However, this reduces internal memory capacity (for screen data) by 1 MB.
- Capacity available for user application. With GP-Pro EX Ver. 2.5 or earlier versions, 8 MB whether or not the Event Recorder Function is in use.
- Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec./month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.
ÀϹݻç¾ç
ÇؿܾÈÀü±Ô°Ý |
|
Á¤°ÝÀü¾Ð |
AC 100 to 240 V |
Àü¾ÐÇã¿ë¹üÀ§ |
AC 85 to 264 V |
Á¤°ÝÁÖÆļö |
50/60 Hz |
Çã¿ë ÁÖÆļö |
40 to 72 Hz |
Çã¿ë ¼ø°£Á¤Áö ½Ã°£ |
1 cycle or less(Voltage drop interval must be 1 second or more.) |
¼Òºñ Àü·Â |
AC 100 V: 110 VA or less, AC 240 V: 168 VA or less |
µ¹ÀÔÀü·ù |
60 A or less |
Àý¿¬³»·Â |
AC 1,500 V 20 mA for 1 min (between charging and FG terminals) |
Àý¿¬ÀúÇ× |
DC 500 V, 10 M¥Ø or more (between charging and FG terminals) |
»ç¿ëÁÖÀ§¿Âµµ |
0 to 50 ¡É |
º¸Á¸ÁÖÀ§¿Âµµ |
-20 to +60¡É |
»ç¿ëÁÖÀ§½Àµµ |
10 to 90 % RH (Wet bulb temperature: 39 ¡É or less - no condensation.) |
º¸Á¸ÁÖÀ§½Àµµ |
10 to 90 % RH (Wet bulb temperature: 39 ¡É or less - no condensation.) |
¸ÕÁö·® |
0.1 mg/m©ø or less (non-conductive levels) |
¿À¿°µµ |
For use in Pollution Degree 2 environment |
ºÎ½Ä¼º °¡½º |
Free of corrosive gases |
³»±â¾Ð |
800 to 1,114 hPa (2,000 m above sea level or less) |
³»Áøµ¿ |
IEC/EN61131-2 compliant, 5 to 9 Hz Single amplitude 3.5 mm [0.14 in.], 9 to 150 Hz Fixed acceleration: 9.8 m/s©÷, X, Y, Z directions for 10 cycles (100 min) |
³»Ãæ°Ý¼º |
IEC/EN61131-2 compliant, 147 m/s©÷, X, Y, Z directions for 3 times |
³» ³ëÀÌÁî |
Noise Voltage: 1,500 Vp-p, Pulse Duration: 1 µs, Rise Time: 1 ns, (via noise simulator) |
³»Á¤Àü±â ¹æÀü |
Contact Discarge Method: 6kV (IEC/EN61000-4-2 Level 3) |
Á¢Áö |
Functional grounding: Grounding resistance of 100¥Ø, 2mm©÷ or thicker wire, or your country's applicable standard. (Same for FG and SG terminals) |
º¸È£ ±¸Á¶ |
Equivalent to IP65f NEMA #250 TYPE 4X/13 (on the front panel when properly installed in an enclosure)*7 |
ÀνºÅç »ç¾ç |
Embedded panel |
³Ã°¢¹æ½Ä |
Natural air circulation |
¹«°Ô |
5.6 kg [12.3 lb] or less (display unit only) |
¿ÜÇüÄ¡¼ö |
W395 x H294 x D60 mm [W15.55 x H11.57 x D2.36 in.] |
ÆгΠÄÆ Ä¡¼ö |
W383.5 x H282.5 mm [W15.1 x H11.12 in.], Panel thickness area: 1.6 to 10 mm [0.06 to 0.39 in.]*8 |
- The front face of the GP unit, installed in a solid panel, has been tested using, conditions equivalent to the standards shown in the specification. Even though the, GP unit's level of resistance is equivalent to these standards, oils that should have, no effect on the GP can possibly harm the unit. This can occur in areas where either, vaporized oils are present, or where low viscosity cutting oils are allowed to adhere, to the unit for long periods of time. If the GP's front face protection sheet becomes, peeled off, these conditions can lead to the ingress of oil into the GP and separate, protection measures are suggested., Also, if non-approved oils are present, it may cause deformation or corrosion of the, front panel¡¯s plastic cover. Therefore, prior to installing the GP be sure to confirm the, type of conditions that will be present in the GP's operating environment., If the installation gasket is used for a long period of time, or if the unit and its gasket, are removed from the panel, the original level of the protection cannot be guaranteed., To maintain the original protection level, be sure to replace the installation gasket, regularly.
- Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.].
|